Insulation “Stenofon 290”

  • Certificate of conformity № РОСС RU.НА36.Н77400 Valid thru 25.10.2021
  • SES Expert opinion № 2420г/2018 dated 16.10.2018
  • Fire safety certificate № C-RU.АБ09.В.00638 Valid thru 02.11.2023
    Flammability group — B2 (moderately flammable) according to GOST (Russian National Standard) 30402-96;
    smoke-forming ability group — D3 (high smoke-forming ability) according to GOST (Russian National Standard) 12.1.044-89 (par.4.18);
    toxicity group — Т3 (highly dangerous) according to GOST (Russian National Standard) 12.1.044-89(par.4.20);
    flame propagation group — RP1 (non-spreading) according to GOST (Russian National Standard) 51032-97. Material flammability class KM4.
  • TU 22.21.41.110-002-09693619-2018 (Russian technical requirements)

Insulation “Stenofon 190”

  • Certificate of conformity № РОСС RU.НА36.Н00565 Valid thru 25.10.2021.
  • SES Expert opinion № 2422г/2018 dated 16.10.2018
  • Fire safety certificate № C-RU.AБ09.В.00639 Valid thru 02.11.2023.
    Burning group — G3 (normally burning)
    Flammability group — B3 (flammable) according to GOST (Russian National Standard) 30402-96;
    smoke-forming ability group — D3 (high smoke-forming ability) according to GOST (Russian National Standard) 12.1.044-89 (par.4.18);
    toxicity group — Т3 (highly dangerous) according to GOST (Russian National Standard) 12.1.044-89(par.4.20).
    Material flammability class KM5.
  • TU №22.21.41.110-001-09693619-2018 (Russian technical requirements)

Insulation “Stenoflex 400”

  • Certificate of conformity № РОСС RU.НА36.Н00563 Valid thru 25.10.2021
  • SES Expert opinion № 2421г/2018 dated 16.10.2018
  • Fire safety certificate № C-RU.AБ09.В.00637 Valid thru 02.11.2023
  • Burning group — G1 (poorly burning) according to GOST (Russian National Standard) 30244-94;
    Flammability group — B2 (normally flammable) according to GOST (Russian National Standard) 30402-96;
    smoke-forming ability group — D3 (high smoke-forming ability) according to GOST (Russian National Standard) 12.1.044-89 (par.4.18);
    toxicity group — Т2 (moderately dangerous) according to GOST (Russian National Standard) 12.1.044-89(par.4.20);

  • Material flammability class KM3.
  • TU №22.21.41.110-003-09693619-2018 (Russian technical requirements)

Insulation “Stenofon NPE” (non-cross-linked expanded polythene)

  • Certificate of conformity № РОСС RU.АГ81.Н00303 Valid thru 11.12.2019
  • SES Expert opinion № 6023 dated 16.12.2013
  • Fire safety declaration №С-RU.ПБ25.В.04217. Valid thru 12.12.2019

Insulation “Stenoflex twisted cord”

  • Certificate of conformity № РОСС RU.НА36.Н00565 Valid thru 25.10.2021
  • SES Expert opinion № 2422г/2018 dated 16.10.2018
  • Fire safety certificate №C-RU.AБ09.В.00639. Valid thru 02.11.2023
  • Burning group — G3 (normally burning) according to GOST (Russian National Standard) 30244-94;
    Flammability group — B3 (highly flammable) according to GOST (Russian National Standard) 30402-96;
    smoke-forming ability group — D3 (high smoke-forming ability) according to GOST (Russian National Standard) 12.1.044-89 (par.4.18);
    toxicity group — Т3 (highly dangerous) according to GOST (Russian National Standard) 12.1.044-89(par.4.20);
  • Material flammability class KM5
  • TU №22.21.41.110-001-09693619-2018 (Russian technical requirements)

Insulation “Stenofon 190-2”

  • Certificate of conformity № РОСС RU.НА36.Н00565 Valid thru 25.10.2021
  • SES Expert opinion № 2422г/2018 dated 16.10.2018
  • Fire safety certificate №C-RU.AБ09.В.00639. Valid thru 02.11.2023
    Burning group — G3 (normally burning) according to GOST (Russian National Standard) 30244-94;
    Flammability group — B3 (highly flammable) according to GOST (Russian National Standard) 30402-96;
    smoke-forming ability group — D3 (high smoke-forming ability) according to GOST (Russian National Standard) 12.1.044-89 (par.4.18);
    toxicity group — Т3 (highly dangerous) according to GOST (Russian National Standard) 12.1.044-89(par.4.20);
    Material flammability class KM5
  • TU №22.21.41.110-001-09693619-2018 (Russian technical requirements)

Insulation “Stenofon Acoustic Vent”

  • Certificate of conformity № РОСС RU.НА36.Н00563 Valid thru 25.10.2021
  • SES Expert opinion № 2421г/2018 dated 16.10.2018
  • Fire safety certificate №C-RU.AБ09.В.00637. Valid thru 02.11.2023
    Burning group — G1 (poorly burning) according to GOST (Russian National Standard) 30244-94;
    Flammability group — B2 (normally flammable) according to GOST (Russian National Standard) 30402-96;
    smoke-forming ability group — D3 (high smoke-forming ability) according to GOST (Russian National Standard) 12.1.044-89 (par.4.18);
    toxicity group — Т2 (moderately dangerous) according to GOST (Russian National Standard) 12.1.044-89(par.4.20);
  • Material flammability class KM3